Product Information
The polluted air is extracted by means of the ventilator and guided towards the filtering section. The toxic particles deposit on the surface of the filter cartridges. The cartridges are dedusted automatically or manually by compressed air.
The particles deposited on the cartridge are detached by the compressed air blast and reach a dust collecting tank. The cleaned air is recycled to the working space via an outlet silencer without any heat loss. Optionally, the air can be guided to the exterior via a two-way branch.
Specification
Width [mm]: | 800 |
Depth [mm]: | 800 |
Length [mm]: | 2860 |
Filter surface [m²]: | 31,2 |
Cartridges number: | 4x 7,8 m² standard |
Engine power (kW): | 2,2 |
Volumetric flow [m³/h]: | 3500 |
Depression [Pa]: | 2700 |
Supply voltage (V): | 400 |
Connection frequency [Hz]: | 50 |
Current consumption (A): | 5 |
Current type: | 3Ph+N+PE |
Cleaning pressure [bar]: | 2 - 4 |
Required compressor capacity [l / min]: | 75 |
Dust container volume [l]: | 50 |
Automatic cleaning: | Yes |